10/11kV Combined CT PT with VCB

Product Parameters:

· Outdoor epoxy resin type combined CT PT · Three phase four wire or three phase three wire · Rated voltage: 3.3kV, 6kV, 10kV, 11kV, 12.5kV, 13.8kV · Metering class for CT: 0.2S, 0.2, 0.3, 0.5, 0.5S, 0.6 ·Metering class for PT: 0.2, 0.3, 0.5, 0.6 · Rated current for relcoser: 630A, 400A, 200A · Standard: IEC, ANSI, GB

General

This outdoor epoxy resin type combined current transformer/voltage transformer metering instrument transformer (metering units, MOF), used in current transformer used in 3.3kV, 6kV, 10kV, 11kV, 12.5kV and 13.8kV power system, for measuring energy, power line protection, and control.

It has been used in outdoor pole mounted and transmission line. The voltage transformer is made from outdoor high quality ultraviolet-proof epoxy resin, high quality CRGO core for metering, primary and secondary use pure electrolytic copper, both winding and core have shielding processing.

This combined instrument transformer can combine from 2 Current transformer and 2 voltage transformers to be 3 phase 3 wire, also can combined from 3 current transformer and 3 voltage transformers to be 3 phase 4 wire.

2 voltage transformer structure use V/V connection, 3 voltage transformer structure use Y/Y connection.

Outdoor vacuum circuit breaker can work as recloser, automatic protection, metering with smart prepaid meter, if no money one prepaid meter, MV power line automatic cut down, if charge money on prepaid meter, power automatic power recovery.

It has default phase protection, overcurrent protection, overvoltage protection, and other relay protection functions.

Standard All UNISUN Electric instrument transformers are in conformity with IEC standards, and recommendations IEC 61869. Transformers in conformity with specific country standards can also be supplied. (IEEE C57.13, NBR6855).

All vacuum circuit breakers conform to the IEC 62271-100, CEI – VDE – BS Standards are equivalent to IE Standards due to harmonization with IEC

Specification data she

Current Transformer

Rated primary current(A)

Accuracy class and output (VA)

Rated short-time thermal current(kA)

Rated dynamic stable current (kA)

5, 10, 15, 20, 25, 30, 40, 50, 75, 100, 150, 200, 300, 400, 600, 800,100

Voltage transformer

Rated primary voltage(kV)

Maximum system voltage(kV)

Rate secondary voltage(V)

Accuracy class and output (VA)

Accuracy class and output (V)

Vacuum Circuit Breaker

Parameter name

Unit

Number of Values

Rated voltage

Max voltage

Rated current

Power frequency withstand voltage (1 min)

Dry

Wet

Rated frequency

Lightning impulse withstand voltage (peak value)

Rated short circuit breaking current

Rated short circuit close current (peak value)

Rated current peak tolerance

4s short-term resistance current

Rated operating sequence

Rated short circuit current open circuit

Times

Mechanical life

The control voltage permanent magnetic actuator

The secondary loop 1 min power frequency withstand voltage

Other types of meeting units

Overall dimension

MainStructure

Primary winding of CT

High electrolytic copper is used as primary winding, silver base welding material is used at the welding place, and semiconductor shielded paper is wrapped to ensure that the partial discharge tseting data is qualified.

Secondary winding of CT

Large capacity design secondary winding, automatic winding, high insulation and high purity enameled wire, to ensure wide capacity output under standard accuracy.

PT Core

Imported silicon steel sheet made of PT core, high quality insulation tape, high quality compression sponge, to ensure that resin shrinkage does not affect the performance of PT core, secondary use of high purity enameled wire.

Primary winding of PT

Mechanized winding secondary winding, all wire uses high purity copper enameled wire, each layer uses high quality insulating paper, to ensure that the layer withstand voltage qualified, to ensure the stability of partial discharge test.